Biotage 221-0100-T ISOLUTE C18(EC) SPE Column – 2 mL, 100 mg
The Biotage 221-0100-T is an ISOLUTE C18(EC) Solid Phase Extraction (SPE) column configured in a standard 2 mL syringe format. Each tube contains 100 mg of a silica-based sorbent covalently bonded with octadecyl (C18) hydrocarbon chains. The sorbent undergoes an exhaustive end-capping process to neutralize residual surface silanols, suppressing secondary polar interactions. This non-polar, reversed-phase chemistry is engineered for the extraction and concentration of non-polar to moderately polar analytes from aqueous matrices.
Technical Performance and Design
-
End-Capped Sorbent: Exhaustive end-capping minimizes secondary cation-exchange interactions with basic analytes, preventing irreversible binding and ensuring high elution recoveries.
-
Reversed-Phase Mechanism: Utilizes strong hydrophobic interactions to retain organic compounds from polar sample matrices such as water, plasma, or urine.
-
Silica Substrate: The standardized particle size and pore geometry (typically 50 µm / 60 Å) ensure consistent liquid flow rates when processed on standard vacuum manifolds or positive pressure systems.
-
2 mL Column Format: The 2 mL reservoir accommodates small aqueous sample volumes while utilizing a minimal 100 mg sorbent bed, drastically reducing the volume of organic solvent required for the final elution step.
Product Specifications
-
Catalog Number: 221-0100-T
-
Product Line: ISOLUTE C18(EC) (End-Capped)
-
Format: 2 mL SPE Column (Syringe Format)
-
Sorbent Mass: 100 mg per tube
-
Retention Mechanism: Non-polar (Hydrophobic)
-
Target Analytes: Non-polar and moderately polar compounds
Key Benefits & Applications
-
Environmental Analysis: Used for the extraction and concentration of trace-level contaminants, such as pesticides, herbicides, and polycyclic aromatic hydrocarbons (PAHs), from surface and drinking water.
-
Bioanalytical Testing: Isolates pharmaceutical drugs, metabolites, and endogenous biomarkers from physiological fluids prior to LC-MS/MS or GC-MS analysis.
-
Aqueous Desalting: Effective for removing salts and polar interferences from aqueous sample mixtures before downstream mass spectrometry or lyophilization.
-
Solvent Efficiency: The compact 100 mg bed mass reduces solvent consumption during the conditioning, washing, and elution phases, shortening subsequent evaporation and dry-down times.