Description

Clarkson HI98188-01
EC/Resistivity/TDS/NaCl Meter with USP 115V
Hanna Instruments HI 98188-01

  •  Autorange from 0.001 µS/cm to 1,000 mS/cm (actual EC)
  • Ready to perform all three stages of USP <645> method required for EC measurement of pure and ultra pure water
  • Linear, natural water, or no temperature compensation
  • Memorize up to ten user profiles
  • Log on demand and autolog; All logged data can be transferred to PC through USB port.
  • GLP features
  • Backlit, graphic display

HI 98188 is a waterproof, portable conductivity meter that has an expanded conductivity range from 0.001 µS/cm to 400 mS/cm,
as well as TDS, resistivity and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows
the user to adjust the nominal cell constant. HI 98188 is also ready to perform all three stages of USP <645> method required for
EC measurement of pure and ultrapure water.

Choose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI 7037 standard
allows users to make a one point calibration.

EC and TDS measurements are fully customizable and include: cell contant selection between 0.0 and 10.000, selection of linear or 
natural water (non-linear) or no (for actual conductivity reading) temperature compensation, configurable temperature compensation
coefficient range from 0.00 to 10.00%/ºC, choice of reference temperatures of of 15ºC, 20ºC and 25ºC and a selectable
TDS factor between 0.40 and 1.00.

Ten sets of customized measurement parameters can be stored as a user profile and recalled for later use.

Data may be captured by either the log on demand option (400 samples) or by interval logging (from 5 sec to 1 minute).
Data can be transferred to a PC using HI 92000 software and HI 920013 USB cable.

A combination of dedicated and soft keys allows quick, intuitive operation in a choice of languages. Comprehensive GLP data is directly
accessible by pressing the GLP key. At the touch of a button users can access the contextual help menu to obtain on-screen information
and assistance about each feature.

Designed for field use, this instrument can be easily operated with one hand and includes a rugged carrying case. With an extended
battery life of up to 100 hours, users are assured long operation. The inductive charger can either be plugged into a standard 115V socket
with the adapter included or a 12 Vdc source, such as a car’s 12 volt accessory outlet.

Specifications:

Range EC 0.001 µS/cm to 400 mS/cm (actual conductivity 1000 mS/cm) 0.001 to 9.999 µS/cm; 10.00 to 99.99 µS/cm;
100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual EC) (autoranging)
Resistivity 1.0 to 99.9 Ohms; 100 to 999 Ohms; 1.00 to 9.99 KOhms; 10.0 to 99.9 KOhms; 100 to 999 KOhms;
1.00 to 9.99 MOhms; 10.0 to 100.0 MOhms (autoranging)
TDS 0.00 to 99.99 mg/L (ppm); 100.0 to 999.9 mg/L (ppm); 1.000 to 9.999 g/L (ppt); 10.00 to 99.99 g/L (ppt);
100.0 to 400.0 g/L (ppt) (autoranging)
NaCl %: 0.0 to 400.0%; seawater scale: 0.00 to 80.00 (ppt); practical salinity: 0.01 to 42.00 (PSU)
Temperature -20.0 to 120.0°C
Resolution EC 0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
Resistivity 0.1 Ohm; 1 Ohm; 0.01 KOhms; 0.1 KOhms; 1 KOhms; 0.01 MOhms; 0.1 MOhms
TDS 0.01 mg/L (ppm); 0.1 mg/L (ppm); 0.001 g/L (ppt); 0.01 g/L (ppt); 0.1 g/L (ppt)
NaCl 0.1%; 0.01
Temperature 0.1°C
Accuracy @ 25°C EC ±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater)
Resistivity ±1% of reading (±10 Ohms or 1 digit, whichever is greater)
TDS ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
NaCl ±1% of reading
Temperature ±0.2°C (excluding probe error)
Temperature Compensation -20.0 to 120.0°C
Reference Temperature 15°C, 20°C and 25°C
Temperature Coefficient 0.00 to 10.00 %/°C
TDS Factor 0.40 to 1.00
Probe HI 76313 platinum, four ring conductivity/TDS probe with internal temperature sensor, DIN connector
and 4 m (13.1′) cable (included)
Logging Log on Demand 400 samples
Lot Logging 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles up to 10
Measurement Modes autorange, autoend, LOCK and fixed range
PC Connectivity opto-isolated USB (with HI 92000 software)
Battery Type / Life 1.2V AA rechargeable batteries (4) / approximately 100 hours of continuous use (without backlight);
user selectable auto-off: 5, 10, 30, 60 minutes or disabled
Environment IP67
Dimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)
Weight 525 g

 

Accessories:

Solutions
HI 7030L 12880 µS/cm EC Solution, 500 mL Bottle
HI 7031L 1413 µS/cm EC Solution, 500 mL Bottle
HI 7033L 84 µS/cm EC Solution, 500 mL Bottle
HI 7034L 80000 µS/cm EC Solution, 500 mL Bottle
HI 7035L 111800 µS/cm EC Solution, 500 mL Bottle
HI 7039L 5000 µS/cm EC Solution, 500 mL Bottle
HI 7035L 111800 µS/cm EC Solution, 500 mL Bottle
HI 70442L 1500 mg/L (ppm) TDS Solution, 500 mL Bottle
HI 7036L 12.41 g/L (ppt) TDS Solution, 500 mL Bottle
HI 7037L Calibration Solution for % Readings (100% NaCl)
HI 7061L General Purpose Cleaning Solution 1 x 500 mL bottle
Accessories
HI 92000 Windows® Compatible Software
HI 920013 USB Cable
Probes
HI 76313 4-ring Platinum Conductivity/TDS Probe for use with HI 98188

Order Information:
HI 98188-01 (115V) and HI 98188-02 (230V) are supplied with HI 76313 conductivity probe, 100 mL plastic beaker,
HI 7031M 1413 mS/cm calibration solution (230 mL), HI 7035 111.8 mS/cm calibration solution, rechargeable batteries,
12 VDC adapter/ charger, instructions and rugged carrying case. HI 98188/10M (230V) is supplied with everything above
but includes a HI 76313 probe with 10 m (32.8’) cable in place of the standard cable length.

Downloads:
Manual: (Download)

Reviews

There are no reviews yet.

Be the first to review “EC/Resistivity/TDS/NaCl Meter with USP 115V”

Your email address will not be published. Required fields are marked *